Panasonic KX-TD500 User Manual
Page 29
Configuration
Programming Guide
29
Parameter
Card No.
Default
—
Value Range
XXX : E1 [ XXX : Card No. (101-314)]
Description/Function
Specifies the physical number of the E1 digital trunk card which
you are going to programme.
Reference
• 1.2
Slot Assignment (P/G)
Parameter
Channel Type
Default
Undefined
Value Range
1.
Undefined
2.
DR2
3.
E&M-P
4.
E&M-C
Description/Function
Specifies the type of E1 interface per channel.
1.
Undefined: Not assigned.
2.
DR2: Digital signalling system-R2
3.
E&M-P: Pulsed E&M
4.
E&M-C: Continuous E&M
Reference
• 1.3 System Features (F/G)
– E1 Carrier
Parameter
Group No.
Default
Blank
Value Range
1-48
Description/Function
Specifies the Trunk Group (1-48) to which the E1 port is assigned.
Reference
• 1.3 System Features (F/G)
– Trunk Group
• 3.2
Trunk Group (P/G)