Panasonic KX-TD500 User Manual
Page 157
Group
Programming Guide
157
Parameter
Search Mode
Default
UCD
Value Range
1.
UCD
2.
Sequential
Description/Function
Specifies the search mode for extensions.
(Assignable only when "Operator (Single)" or "UCD" is specified
in "Group Type" programming.)
1.
UCD:
The system selects the extension following the last one called as
the destination extension.
2.
Sequential:
The system selects the extension assigned first in the Incoming
Group as the destination extension.
Reference
• 1.3 System Features (F/G)
– Incoming Group
• 1.5 Attended Features (F/G)
– Uniform Call Distribution (UCD)
• 1.6 Originating Features (F/G)
– Operator Call
Parameter
Calls to Empty Group
Default
Disable
Value Range
1.
Enable
2.
Disable
Description/Function
Allows for calls to empty (all Logout) Operator or UCD Groups to
be queued.
If enabled, calls will be queued to the group.
If disabled, the extension will receive a reorder tone, and the CO
call will be transferred to the overflow destination immediately.
(Assignable only when "Operator" or "UCD" is specified in "Group
Type" programming.)
Reference
• 1.3 System Features (F/G)
– Incoming Group
– Operator Group
• 1.5 Attended Features (F/G)
– Uniform Call Distribution (UCD)