◆ Dryer Test — runs the dryer heater assembly to test for cor-
rect operation.
◆ Print Image on Image Sensor — the printer prints a small set
of lines which are scanned by the digital image sensor. Then
the printer prints an enlargement of the image as the sensor
captured it.
◆ Horizontal Dot Accuracy — for factory/service use only.
◆ Vertical Dot Accuracy — for factory/service use only.
◆ Isolation Print Test — for factory/service use only.
◆ Pod Test — for factory/service use only.
Calibrations
These calibrations are performed at the factory. If any of them
are detected as out-of-specification, a message is displayed on
the control panel, recommending that you perform the applica-
ble calibration:
◆ Head Height — re-homes the head height to the known
highest reference point, or if New Carriage was previously
selected (see below), recalibrates the known highest refer-
ence point
◆ Media Sensor — locates the platen to establish the “media
out” head height
◆ White Point — reads the white point reference chip in the
platen to establish a white point for the photo diode.
Home Head
Recalibrates the home position of the printhead carriage. If the
printhead carriage will not return to the service station between
prints, select this option. Cycling the power off and on will also
run the Home Head function.
Measure Media Width
Measures the width of the media.
New Carriage
Reinitializes the head height so that it can be recalibrated (see
“Calibrations,” above.
Prime Bars
Prints a wide-swath version of the prime bars.