Electrical Requirements - U.S.A.

Only

WARNING

Electrical Shock Hazard

Electrically ground appliance.
Failure to do so could result in death, fire, or electrical

shock.

Be sure that the electrical connection and wire size are adequate

and in conformance with the National Electrical Code,

ANSI/NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

WARNING:

Improper connection of the equipment-grounding

conductor can result in a risk of electric shock. Check with a

qualified electrician or service technician if you are in doubt as to

whether the appliance is properly grounded. Do not modify the

power supply cord plug. If it will not fit the outlet, have a proper

outlet installed by a qualified electrician.

Electrical Connection

Check local codes and consult gas supplier. Check existing

electrical supply and gas supply. See “Gas Supply Requirements”

section.
It is recommended that all electrical connections be made by a

licensed, qualified electrical installer.

Range must be connected to the proper electrical voltage and

frequency as specified on the model/serial/rating plate. The

model/serial/rating plate is located behind the oven door on the

top right-hand side of the oven frame.

A.

Model/serial/rating plate (located behind the oven door on the top
right-hand side of the oven frame)

This range is manufactured with a 4-wire power supply cord

rated at 240 V, 40 A, rated at 194°F (90°C) and investigated for

use with this range.

Range Rating*

Specified Rating of

Power Supply Cord Kit

and Circuit Protection

120/240 V

120/208 V

Amps

8.8-16.5 kW

7.8-12.5 kW

40 or 50**

16.6-22.5 kW

12.6-18.5 kW

50

*The NEC calculated load is less than the total connected load

listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit.

For 50 A rated cord kits, use kits that specify use with a

nominal 1

3

/

8

" (34.9 mm) diameter connection opening.

When a 4-wire, single phase 240 V, 60 Hz, AC only electrical

supply is available, a 40 A minimum circuit protection is

required on 30" (76.2 cm) ranges, fused on both sides of the

line.

A time-delay fuse or circuit breaker is recommended.

This range is equipped with a UL or CSA International Certified

Power Cord intended to be plugged into a standard 14-50R

wall receptacle. Be sure the wall receptacle is within reach of

range’s final location.

Do not use an extension cord.

The wiring diagram is located on the back of the range or in a

clear plastic bag.

Electrical Requirements - Canada

Only

WARNING

Electrical Shock Hazard

Electrically ground appliance.
Failure to do so could result in death, fire, or electrical

shock.

Be sure that the electrical connection and wire size are adequate

and in conformance with CSA Standard C22.1, Canadian

Electrical Code, Part 1 - latest edition, and all local codes and

ordinances.
A copy of the above code standards can be obtained from:

Canadian Standards Association

178 Rexdale Blvd.

Toronto, ON M9W 1R3 CANADA

9