[Controller out terminal]
Displays the terminal used for the remote control
communication output.
Set each item.
1
0
192.168.0.8
Multi control auto setting(DIGITAL LINK)
Status
Display ID
Start
Network control / IP address
Display ID
Wait
Yes
Off
Changing network control
Yes
Changing Serial/IR terminal
Serial ID / Terminal
On
SERIAL IN
Serial out terminal
SERIAL OUT
Controller ID / Terminal
On
Built-in
Controller out terminal
IR OUT
DIGITAL LINK daisy chain
020/025
[Display ID]
Sets the ID you want to assign to the display you are
operating.
[Auto], 1 to 100
When setting to [Auto], the ID is set using the
number counted from the first unit connected with
the DIGITAL LINK daisy chain.
Example: 15th unit counted from the beginning
ID: 15
Note
●
When connected with the DIGITAL LINK daisy chain,
the ID number and control terminal are automatically
set for the preceding-stage display before the display
on which the operation is performed.
[Changing network control]
Sets whether to change settings in [Network control]
or maintain the current settings.
[No]:
Maintains the settings.
[Yes]:
Switches [Network control] to [On] when it is set to
[Off], and switches [DHCP] to [On].
[Changing Serial/IR terminal]
Sets whether to change the control terminal setting
or maintain the current setting when performing auto
setup.
[No]:
Maintains the settings.
[Yes]:
The setting of each IN/OUT terminal
connected via DIGITAL LINK are changed to
[DIGITAL LINK].
Note
●
If there is a terminal connected with the DIGITAL
LINK daisy chain on the display with only the input
side or the output side connected, the setting will be
changed.
Select [Start] and press
Starts auto setting.
The following screen is displayed when the setting
is completed.
1
192.168.0.8
Multi control auto setting(DIGITAL LINK)
Status
DIGITAL LINK daisy chain
Network control / IP address
Finished
On
Display ID
020/025
●
When [DHCP] is set to [On], IP address is updated
automatically.
The following screen is displayed on the subsequent-
stage displays.
2
192.168.0.9
Multi control auto setting(DIGITAL LINK)
Status
Display ID
Network control / IP address
Finished
On
DIGITAL LINK daisy chain
021/025
●
For each subsequent-stage display, an ID number
with 1 added to the ID number of each preceding-
stage display is assigned.
If the ID number of the preceding-stage display is
“100”, ID number “1” is set.
●
When [DHCP] is set to [On], IP address is updated
automatically, so check it again on [Network status]
screen, etc.
Note
●
This function is available only when the main software
version is 1.2000 or later.
This function changes SERIAL IN/OUT terminals, IR
IN/OUT terminals and the network function.
To use the DIGITAL LINK terminal and the network
function in standby state, it is necessary to set [Quick
start] to [On].
[IR control] (see page 53)
[IR out] (see page 54)
[Serial control] (see page 54)
[Serial out] (see page 54)
[Network control] (see page 69)