beautypg.com

ProSoft Technology 5201-DFNT-104C User Manual

Page 101

background image

104C Version 3 ♦ ProLinx Gateway

Diagnostics and Troubleshooting

IEC 60870-5-104 Client (Firmware v3.xx)

Protocol Manual

ProSoft Technology, Inc.

Page 101 of 139

August 4, 2011

Viewing Data in Decimal Format
Press [D] from the Database View menu to display the data on the current page
in decimal format.

Viewing Data in Hexadecimal Format
Press [H]

from the Database View menu

to display the data on the current page

in hexadecimal format.

Viewing Data in Floating-Point Format
Press [F]

from the Database View menu to display the data on the current page

in floating-point format. The program assumes that the values are aligned on
even register boundaries. If floating-point values are not aligned as such, they
are not displayed properly.

Viewing Data in ASCII (Text) Format
Press [A]

from the Database View menu to display the data on the current page

in ASCII format. This is useful for regions of the database that contain ASCII
data.

Returning to the Main Menu
Press [M]

to return to the Main menu.

5.2.6 IEC-870-5-104 Client Menu

Press [

Q

]

from the main menu to open the IEC-870-5-104 Client Menu.