5) Enable Hysteresis

• A checkbox to enable the hysteresis of the Mesh AP
• Link hysteresis determines the criteria at which a link to a neighbour is

accepted or rejected. Hysteresis adds more robustness to the link sensing,

but delays the neighbour registration.

6) Hysteresis Scaling

• The level scale of the hysteresis
• Data type: Float (0.0 ~ 1.0)

7) Hysteresis THR High

• The upper limit (threshold high) of the hysteresis
• Data type: Float (0.0 ~ 1.0)

8) Hysteresis THR Low

• The lower limit (threshold low) of the hysteresis
• Data type: Float (0.0 ~ 1.0)

9) Link Quality Type

• The type of link quality
• Available options:

o

Disable

o

Use for MPR selection

o

Use for MPR selection and Routing

10) Link Quality Size

• The Link quality window size
• Data type: Integer, default size is 10

11) Poll Rate

• The polling rate, where the value is in the interval of 0 and 1
• Data type: Float

12) TC Rate

• The TC redundancy specifies the level of neighbour information should be

sent in a TC message.

• Available options: