beautypg.com

Erps guard-timeout, Erps wtr-timeout – PLANET MGSW-28240F User Manual

Page 616

background image

User’s Manual of MGSW-28240F

erps guard-timeout

Description:

Configuring guard timeout for a protection group guard timeout should be configured in the increments of 10 milliseconds

minimum guard timeout 10ms and maximum 2 seconds.

: guard timeout.

: protection group id for configuring guard time.

Syntax:

Erps guard-timeout

Parameters:

: timer timeout values.

: protection group id 1 – 64.

Example:

MGSW-28240F:/>erps guard-timeout 500 1

erps wtr-timeout

Description:

Configuring wait to restore timeout for a protection group in minutes in the range of 1 to 12 minutes.

: configuring wtr timeout.

: protection group id for configuring wtr time.

Syntax:

Erps wtr-timeout

Parameters:

: timer timeout values.

: protection group id 1 – 64.

616