beautypg.com

PLANET MGSW-28240F User Manual

Page 376

background image

User’s Manual of MGSW-28240F

R-APS messages.

The period of the guard timer can be configured in 10 ms steps between 10 ms

and 2 seconds, with a default value of 500 ms

WTR Time

The Wait To Restore timing value to be used in revertive switching.

The period of the WTR time can be configured by the operator in 1 minute steps

between 5 and 12 minutes with a default value of 5 minutes.

The timing value to be used to make persistent check on Signal Fail before

switching.

Hold Off Time

The range of the hold off timer is 0 to 10 seconds in steps of 100 ms

Version

ERPS Protocol Version - v1 or v2

In Revertive mode, after the conditions causing a protection switch has cleared,

the traffic channel is restored to the working transport entity, i.e., blocked on the

RPL.

Revertive

In Non-Revertive mode, the traffic channel continues to use the RPL, if it is not

failed, after a protection switch condition has cleared.

VLAN Config

VLAN configuration of the Protection Group. Click on the "VLAN Config" link to

configure VLANs for this protection group.

PRL Configuration:

Object

Description

It can be either RPL owner or RPL Neighbour.

PRL Role

This allows to select the east port or west port as the RPL block.

PRL Port

Clear

If the owner has to be changed, then the clear check box allows to clear the RPL

owner for that ERPS ring.

Instant Command:

Object

Description

Administrative command. A port can be administratively configured to be in either

manual switch or forced switch state.

Command

Port

Port selection - Port0 or Port1 of the protection Group on which the command is

applied.

Instant State:

Object

Description

376