beautypg.com

Dido fault enable, Dido fault port alarm, Dido fault power alarm – PLANET MGSW-28240F User Manual

Page 603

background image

User’s Manual of MGSW-28240F

DIDO Fault Enable

Description:

Set or show the system fault alarm.

Syntax:

DIDO Fault_en [enable|disable]

Parameters:

enable

: Enable digital input0/1 function

disable

: Disable digital input0/1 function

(default: Set or show digital input/output/fault alarm 0/1 status)

DIDO Fault Port Alarm

Description:

Set or show the system fault alarm of port alarm.

Syntax:

DIDO Fault_port_alr []

Parameters:

: Port list or 'all', default: All ports

DIDO Fault Power Alarm

Description:

Set or show the system fault alarm of power alarm.

Syntax:

DIDO Fault_pwr_alr [dc1|dc2] [enable|disable]

Parameters:

dc1

: DC power 1

dc2

: DC power 2

(default: Set or show digital output/fault alarm 0/1 power_fail)

enable

: Enable digital input0/1 function

disable

: Disable digital input0/1 function

603