BPDU Guard

If enabled, causes the port to disable itself upon receiving valid BPDU's. Contrary

to the similar bridge setting, the port Edge status does not effect this setting.

A port entering error-disabled state due to this setting is subject to the bridge Port

Error Recovery setting as well.

Controls whether the port connects to a point-to-point LAN rather than a shared

medium. This can be automatically determined, or forced either true or false. A

transition to the forwarding state is faster for point-to-point LANs than for shared

media. All means all ports will have one specific setting.

Point-to-Point

Buttons

: Click to save changes.

: Click to undo any changes made locally and revert to previously saved values.

By default, the system automatically detects the speed and duplex mode used on each port, and configures the path cost

according to the values shown below. Path cost “0” is used to indicate auto-configuration mode. When the short path cost

method is selected and the default path cost recommended by the IEEE 802.1w standard exceeds 65,535, the default is set to

65,535.

Port Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

50-600

200,000-20,000,000

Fast Ethernet

10-60

20,000-2,000,000

Gigabit Ethernet

3-10

2,000-200,000

Table 4-7-1:

Recommended STP Path Cost Range

Port Type

Link Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

Half Duplex

Full Duplex

Trunk

100

95

90

2,000,000

1,999,999

1,000,000

Fast Ethernet

Half Duplex

Full Duplex

Trunk

19

18

15

200,000

100,000

50,000

Gigabit Ethernet

Full Duplex

Trunk

4

3

10,000

5,000

Table 4-7-2:

Recommended STP Path Costs

166