Table 1.3 transmission mode distance requirements, 1 features, Features – Avago Technologies LSI53C140 User Manual
Page 16: Transmission mode distance requirements

1-6
Using the LSI53C140
Ver. 2.1
Copyright © 1998–2001 by LSI Logic Corporation. All rights reserved.
shows the various distance requirements for each transmission
mode.
1.2.1 Features
The LSI53C140 supports these features:
•
Any combination of LVD, SE, or HVD transceivers
•
Creates distinct SCSI bus segments that are electrically isolated
from each other
•
Integrated LVDlink transceivers for direct attachment to either LVD,
SE, or HVD bus segments
•
Operates as a SCSI Bus Expander
–
LVD to LVD (Ultra2 SCSI)
–
HVD to HVD (Ultra SCSI)
–
SE to SE (Ultra SCSI)
•
Operates as a SCSI Bus Converter
–
LVD to HVD (Ultra SCSI)
–
LVD to SE (Ultra SCSI)
–
HVD to SE (Ultra SCSI)
•
Targets and initiators may be located on either the A or B Side of the
device
Table 1.3
Transmission Mode Distance Requirements
Segment
Mode
Length Limit
A, D
LVD (Ultra2)
25 meters
SE (Ultra)
1.5 meters
HVD (Ultra)
25 meters
B, C
LVD (Ultra2)
12 meters
SE (Ultra)
1.5 meters
HVD (Ultra)
12 meters
- MGA-725M4 (4 pages)
- MGA-71543 (4 pages)
- MGA-71543 (3 pages)
- MGA-82563 (6 pages)
- 3ware SAS 9750-8i (48 pages)
- 3ware 9690SA-8I (Channel) (138 pages)
- 3ware 9690SA-8I (Channel) (380 pages)
- 3ware SAS 9750-8i (29 pages)
- 3ware 9550SXU-8LP (Channel) (149 pages)
- 3ware 9550SXU-8LP (Channel) (40 pages)
- 3ware 9650SE-8LPML (Channel) (45 pages)
- 3ware 9690SA-8I (Channel) (27 pages)
- 3ware 9690SA-8I (Channel) (361 pages)
- 6160 SAS Switch (2 pages)
- Cache Protection for RAID Controller Cards (139 pages)
- Cache Protection for RAID Controller Cards (13 pages)
- MegaRAID SAS 9271-8iCC (13 pages)
- MegaRAID SAS 9361-8i (13 pages)
- MegaRAID SAS 9266-8i (12 pages)
- MegaRAID SAS 9380-8e (43 pages)
- MegaRAID SAS 9271-8iCC (26 pages)
- MegaRAID SafeStore Software (502 pages)
- MegaRAID SAS 9285-8ecv (80 pages)
- MegaRAID SAS 9285-8ecv (92 pages)
- MegaRAID SAS 9266-8i (20 pages)
- MegaRAID SAS 0260CV-4i (49 pages)
- MegaRAID SAS 9271-8i (8 pages)
- MegaRAID SAS 0260CV-4i (72 pages)
- MegaRAID SAS 0260CV-4i (64 pages)
- MegaRAID SAS 9361-8i (7 pages)
- MegaRAID SAS 9341-8i (8 pages)
- MegaRAID SAS 9380-4i4e (7 pages)
- MegaRAID SAS 9380-8e (7 pages)
- MegaRAID SAS 9240-8i (4 pages)
- MegaRAID SAS 0260CV-4i (28 pages)
- MegaRAID SAS 9260-16i (12 pages)
- MegaRAID SAS 9280-24i4e (14 pages)
- MegaRAID SAS 9280-24i4e (16 pages)
- MegaRAID SAS 9260-8i (4 pages)
- MegaRAID SafeStore Software (8 pages)
- MegaRAID SAS 9280-8e (22 pages)
- MegaRAID SAS 9261-8i (4 pages)
- MegaRAID SAS 9285-8e (12 pages)
- MegaRAID SAS 9280-16i4e (12 pages)
- MegaRAID SAS 9280-4i4e (4 pages)