Problems / Causes / Solutions

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

PROBLEM

POSSIBLE CAUSES

REMEDY

Radiators cold in

winter

1. Room thermostat (local or remote)

set too low. If remote thermostat,

check if it is defective.

2. Circulator does not run because

blocked.

3. Circulator does not run.

4. Radiators have air in them

1.

Set to higher temperature or

replace. (if remote)

2. Free up the circulator by removing

the plug and turning the shaft with a

screwdriver.

3. Check the electrical connections of

the circulator; replace if necessary.

4. Vent the radiators

High variability of

temperature of

domestic hot water

1. Water flow rate too low.

1. Increase the water flow rate

(minimum 3 litres per minute)

Little domestic hot

water is provided

1. Insufficient mains pressure

2. Tap or mixer clogged with limescale
3. Water group clogged

1. Check the calibration of the

pressure reducer.

2. Install and autoclave
3. Check and clean
4. Clean or replace the plate heat

exchanger

Hot water is not

provided

1. Circulator (pump) blocked

1. Free the circulator (pump)

ATTENTION!
The operations

in italics must be carried out by

specialised MCZ personnel.