Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

SET

TURBO

1

2

6

4

3

5

!

Al ar

4.10.2. Operating modes

The AUTOMATIC mode lets you set a certain temperature to be

reached. In this operating mode the stove will automatically vary the

thermal power provided so as to keep the temperature in the room

constantly at the previously set value.
As previously described, the temperature is adjusted using the buttons

n

and

o,

in steps of 1 degree centigrade.

Also front ventilation, which is active in automatic mode only when the

stove is hot, is divided into 5 speeds. It can be controlled using the
buttons

p

and

q.

The speed of the fan will be shown for a few

seconds on the display (8).
This setting will be maintained at the next lighting.

Operating example:
If the ambient temperature measured by the local probe on the stove is

15°C, and the temperature set on the thermostat is 22°C, the stove will

sequentially go to maximum power. Upon reaching the requested fixed

temperature (22°C), the stove will go back to minimum power or it will

enter ECO-STOP mode

(See paragraph 4.9.3)

It must be remembered however that the temperature keyed into the

thermostat is only indicative, and it is up to the user to find the correct

setting in the location where the stove is installed (for example, to

achieve 22°C in the room, it may be necessary to set the thermostat on

the stove to 20°C). This is because the ambient thermostat is located

near the body of the stove; therefore, it detects the heat radiated from

the stove.
In this mode, lighting and shutdown are performed by the user, by
pressing button

r

for a few seconds.

It is advisable to inspect the contents of the hopper from time to time,

to keep the fire from going out due to lack of fuel.

ATTENTION!
If, while the stove is running, conditions occur which

modify the normal state of operation, the general

alarm LED (7) lights up, accompanied by an audible

'beep' (see the paragraph on "Lockout of the stove"),

and the stove reacts by starting the process of

complete shutdown.

In the event of an electrical power outage during

lighting or operation, the stove goes into a cooling-off

stage and later automatically relights itself.

Stove in alarm and in lockout status

Adjustment of thermostat temperature (temperature to

be reached in the room)

SET

TUR BO

1

2

6

4

3

5

!

SET

22°C

Adjustment of the speed of the front fan

SET

TURBO

1

2

6

4

3

5

!

AIR4

22°C