beautypg.com

MCZ Athos HYDRO 14 kW User Manual

Page 54

background image

PELLET STOVES

Chapter 4

INSTALLATION AND USE MANUAL

page

54

Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

Flow switch

Plate heat
exchanger

3-way
deviator
valve

The actual shutdown of the stove only occurs 20 - 30 minutes later,

and in any case not before the smoke temperature drops below 50 °C.
This occurs to allow the combustion fumes to be ducted into the flue

pipe by means of the extractor.
It also means that there is total recovery of the heat yielded by

combustion to the structure of the stove.

4.14. DOMESTIC WATER PRODUCTION KIT (optional) For POLAR-NOVA-ATHOS

POWER stoves only

The POLAR and NOVA stoves can also be equipped with a complete kit

for the production of domestic hot water, which is composed of:

Plate heat exchanger

3-way deviator valve

Flow switch

Pipes and fittings for connection


The kit is pre-assembled by the manufacturer, MCZ. Its purpose is to

heat domestic water from the water line of the home.
When a hot water faucet is opened, the internal flow meter orders the

deviator valve to send the hot water in the boiler to the plate heat

exchanger. The temperature of the hot water depends a great deal on

the temperature of the heating system. As a guideline, it can be

calculated by subtracting 10°-15°C from the value shown on the control

panel of the stove (temperature of water in boiler).

If the stove is in ECO-STOP status and there is a request for domestic

hot water, 30 seconds after the request the stove automatically starts

the lighting sequence to heat the water in the boiler and then the

domestic hot water.

For long-lasting operation of the plate heat

exchanger, you need to know the water hardness of

your system in order to prevent incrustations.
If the water in your home is very hard, you should

install a water softener upstream (see chapter 3.4.3)
On a yearly basis, you should have the plate heat

exchanger serviced to remove salt and calcium

sediment, or replace the heating plates with new

ones. These spare parts are supplied by MCZ.


This manual is related to the following products: