beautypg.com

Shutting the stove down (end of season) – MCZ Athos HYDRO 14 kW User Manual

Page 57

background image

PELLET STOVES

Chapter 5

INSTALLATION AND USE MANUAL

page

57

Maintenance and cleaning

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

5.2. CLEANING TO BE PERFORMED BY

SPECIALIZED TECHNICIAN

5.2.1. Cleaning of the heat exchanger

With the stove cold, remove the upper side ceramics in majolica to

access the cleaning plugs of the heat exchanger. Open the upper plugs

(

Figure 6) Using a stiff rod or a bottle brush, scrape the inner walls of

the fire box so that the ashes drop into the part below.
Still with the stove cold, open the lower door of the ash compartment,

extract the ash drawer, behind which the large cleaning plug is located

(

Figure 7). Open this plug as well. With a vacuum cleaner, remove all

ash and soot which has built up in the heat exchanger and in the

smoke extraction fan.
Clean the smoke discharge system, especially in the area of the tee

connectors and of any horizontal stretches of pipe.
For information refer to a chimney sweep.

ATTENTION: for your safety, the frequency of

cleaning the smoke discharge system must be

determined on the basis of the use you make of the

stove.

Check the seal of the ceramic fibre gaskets on the door of the stove.
If necessary order new gaskets from your dealer as replacements.
At the end of the season it is necessary to clean the compartment

under the grate and the heat exchanger inside it.
This general cleaning should be carried out at the end of the season in

order to facilitate the general removal of all residues of combustion,

without waiting too long, because with time and humidity these

residues can become compacted.

5.2.2. Shutting the stove down (end of season)

In the period when the stove is out of use it must be

disconnected from the electricity mains. For greater safety,

especially if there are children around, we recommend

removing the power cable from the rear of the stove.

(Figure 8)

Before placing the stove in storage, you should remove all pellets from

the hopper with a vacuum cleaner with a long extension. If the fuel is

left in the hopper, it may get damp, stick together, and be difficult to

light at the beginning of the next season
If the stove is removed form its place of installation it MUST be

placed in a location that is protected from atmospheric agents.

If pressing the main switch (located on the back of the stove) does not

make the control panel display light up, it could mean that the service

fuse needs replacing.

ATTENTION!
Disconnect the electrical cable.

Figure 7 – Lower plug

Figure 8 – Disconnect the stove from the electrical

mains

Figure 6 – Lateral plugs for internal cleaning

This manual is related to the following products: