MCZ Athos HYDRO 14 kW User Manual
Page 58
![background image](https://www.manualsdir.com/files/856918/content/doc058.png)
PELLET STOVES
Chapter 5
INSTALLATION AND USE MANUAL
page
58
Maintenance and cleaning
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
Figure 9 – Switch with fuse box
On the rear of the stove there is a fuse holding compartment which is
located underneath the supply socket. With a screwdriver open the
cover of the fuse holding compartment, and replace the fuse if
necessary (3.15 AT delayed type).
Figure 9
Plug the unit back in and press the main switch.
If the problem persists or occurs again, contact your MCZ retailer.
5.3. CHECK OF INTERNAL COMPONENTS
ATTENTION!
The check of the internal electromechanical
components must be carried out only by qualified
personnel with technical knowledge of electricity and
combustion. If necessary, contact authorized MCZ
retailers.
We recommend that an annual maintenance service is carried out,
preferably under a programmed service contract. The essential part of
this service is a visual and functional check on the following
components:
•
Reduction motor
•
Smoke expulsion fan
•
Smoke sensor
•
Heat-exchanger fan
•
Ignition sparkplug
•
Resettable pellet thermostat
•
Room temperature sensor
•
Pressure switch
•
Motherboard / service card
•
Fuses protecting panel - motherboard - services card
•
Wiring
The following is a summary of the checks and/or maintenance tasks which are indispensable for the correct
operation of the stove.
Parts / interval
Every
day
Every
2-3 days
Every
30 days
Every
60-90 days
Every
1 year
Burner
●
Ash drawer
●
Glass
●
Lower exchanger
●
Complete exchanger
●
Smoke duct
●
Ash drawer door gasket
●
Internal parts
●
Flue pipe
●
Circulation pump
●
Plate heat exchanger
●
Plumbing components
●
Electro-mechanical components
●
Fuse
box