Theoretical notions for installation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

2.5. CONNECTION OF SMOKE DISCHARGE PIPE

When making the hole for the passage of the smoke discharge pipe, it

is necessary to take into account the possible presence of flammable

materials. If the hole will be going through a wall made of wood or any

other material which is sensitive to heat, the INSTALLER MUST first

of all use the special wall union (diam. 13cm minimum) and properly

insulate the pipe of the stove that passes through it, using adequate

insulation materials (thickness 1.3 - 5cm with minimum thermal

conductivity of 0.07 W/m°K).
The same is true if the stove pipe must run through vertical or

horizontal stretches passing in proximity (min. 20cm) to the heat-

sensitive wall.
As an alternative we recommend the use of insulated pipe, which can

also be used on the outside to avoid condensation.
The combustion chamber works in low pressure. The smoke duct for

the discharge of fumes will also be under low pressure when connected

to an efficient flue pipe as directed.

Pipes and unions with suitable gaskets must always

be used, to guarantee a hermetic seal.

All sections of the smoke duct must be inspectable and

removable to enable periodic internal cleaning. Tee

connectors with inspection caps should be used.


Position the stove bearing in mind all the instructions and

considerations above.

IMPORTANT!
All 90 degree changes of direction in the flue pipe

must be fitted with suitable tee connectors to allow

the possibility of inspection (see the pellet stove

accessory list).
It is absolutely prohibited to fit a grille on the end of

the smoke discharge pipe, because it could lead to

poor operation of the stove.
FOR CONNECTION TO THE FLUE PIPE, NOT MORE

THAN 2-3 METRES OF HORIZONTAL PIPE MUST BE

USED AND NOT MORE THAN THREE 90° CURVES

MUST BE USED
NOT ADVISABLE TO EXCEED A LENGTH OF 6 LINEAR

METRES OF PIPE Ø 80 mm.

THE DIRECT DISCHARGE OF THE

COMBUSTION PRODUCTS MUST BE

PROVIDED ON THE ROOF, AND THE SMOKE

DUCT MUST SATISFY THE SPECIFICATIONS

PROVIDED FOR BY CURRENT LAWS AND

STANDARDS ON THE SUBJECT (UNI 10683)

Figure 7 – Back of POLAR/NOVA stove

Figure 8 – Example of installation of POLAR/NOVA stove

Air intake

Smoke outlet

3-5 %

2 - 3 mt. MAX

Ispection cover