Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

4.12.2. Other signals on the display

The following table summarizes that messages that may be shown on the dispaly panel

MESSAGE ON DISPLAY

MEANING

off

The stove is off

fan acc

Initial lighting sequence

load wood

Pellet loading

fire on

Lighting sequence and adjsutment/stabilizing of flame

Eco Stop

The stove automatically shuts down upon reaching the temperature

20 C°

Example of room temperature

62 C°

Example of water temperature

UT 01, UT02,…

user paramters for programming time, time periods, etc.

day1,,,7

Days of the week

set

Setting of stove operating mode (e.g. SET MAN = Stove set to manual)

Alar fan fail

The smoke fan is not operating correctly

stop fire

Automatic cleaning of the brazier in the set period of time

mcz spa

mcz spa

cool fire

The stove is in cooling mode

alar dep fail

The pressure switch has tripped, indicating difficulty in smoke expulsion

alarm smoke probe

The smoke probe is not working correctly

alar no acc

An ignition attempt has failed.

alar no fire

There is no fire stove

alar fail sic

Thermal alarm Excessive heat in the structure

4.12.3. Lockout of the stove

The following things can cause the stove to lock out:

Overheating of the structure and of the pellet hopper

Overheating of the water in the boiler (T>85°C)

High pressure in the outlet fumes (as read by the pressure

switch) and therefore possible obstruction of the smoke

discharge system or external back-pressure.

Pressure in system less than or greater than the minimum or

maximum parameters of operation

The lockout is indicated by the LED (7) lighting up, accompanied by a

beep.
In this situation the shutdown cycle is automatically activated.
Once this process has started, any attempt to reset the system is

useless. The cause of the lockout is shown on the display (8).

4.12.3.1.

Boiler bulb thermostat

The stove goes into a safety ALARM state called “ALAR SIC FAIL” due

to the water temperature being too high.

MANUAL RESET THERMOSTAT
With the stove cold
, in order to carry out the manual reset, you

must unscrew the cap of the thermostatic probe on the back and

press the red button to reset. You will hear a "click" of the

thermostat. Then put the protection cap back in place.

Figure 7 and

8.

Figure 7 - Touche de réarmement de la sonde à

boule

Figure 8 - Comment réarmer le thermostat à

boule une fois que le poêle est froid.