Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

SET

TURBO

1

2

6

4

3

5

!

OFF

20 41

:

4.12.3.2.

Pellet hopper safety thermostat

If the pellet hopper overheats, the stove goes into a safety ALARM

state called “ALAR SIC FAIL”.
T
he MCZ stoves are provided with two types of safety thermostats:

manual reset

self-reset

If there are two thermostats (see fig. 7 and fig. 8) on the back of the

stove, near the ON button, then the hopper thermostat is a manual

reset thermostat. If, instead, there is only the hopper safety thermostat

on the back panel, then it is self-resetting. (fig.9).

MANUAL RESET THERMOSTAT
With the stove cold
, in order to carry out the manual reset, you

must unscrew the cap of the thermostatic probe on the back and

press the red button to reset. You will hear a "click" of the

thermostat. Then put the protection cap back in place.

Figure 7 and

8.

SELF-RESETTING THERMOSTAT
In this case the stove is equipped with a self-resetting sensor

which intervenes in case of high temperature.

To cancel the alarm condition, the user must shut down the stove

using the button “5” and wait for the stove body and the hopper to

cool in order to allow the self-resetting of the thermostat (about 20

minutes after the occurrence of the alarm). At this point it is

possible to light the stove again.


4.12.3.3.

Smoke expulsion

If you see the message “ALAR DEP FAIL”:
check the ENTIRE smoke duct, including the combustion chamber,

to see that they are clean and free of obstructions. (it is

recommended that this operation be conducted by a specialist MCZ

technician).
Only after the cause of the blockage has been permanently

eliminated can a fresh attempt to relight the stove be made.

4.13. SHUTTING THE STOVE DOWN

The stove can be extinguished at any time and in any position.

NEVER SHUT THE STOVE DOWN BY CUTTING OFF THE

ELECTRICITY SUPPLY:
Always leave it to complete the shutdown cycle,

otherwise damage could be caused to the structure,

and also problems with lighting in the future.

To extinguish the stove, press for a few seconds on the key

r

.

The display (8) will show the message “OFF”. At this moment the

shutdown cycle begins, in which the pellet loading screw stops, while

the smoke extractor and the hot air exchanger remain on until the

temperature of the stove has dropped.