ALAR

Attention!

If the stove is NOT used as described in this instruction

booklet, the manufacturer refuses to accept any responsibility

for damage to persons and property that may arise. The

manufacturer furthermore refuses to accept responsibility for

damage to persons and property arising from the failure to

observe all the rules contained in the manual and in particular

inthe following situations:

Failure when carrying out works of maintenance,

cleaning and repair to adopt all necessary measures and

precautions.

Safey devices are removed or tampered with.

The stove is not connected to a workign, efficient smoke

exhaust system.

The room of installation is not properly ventilated

The plumbing system is not compliant with current law in

the country of installation

4.12.1. Alarm signalling

If an operating anomaly occurs, the stove is equipped with a

computerized monitoring system that informs the user via the display

(8) of the nature of the problem and where it has occurred.
The following table summarises the principal alarms which may be

indicated

Message on the

display (8)

Type of problem

Solution

ALAR DEP FAIL

Obstruction of smoke discharge duct or negative pressure

caused by wind.

Check and clean the ENTIRE smoke duct, or check that

the wind outdoors is not preventing the release of

smoke. Install a wind cowl.

ALAR FAN FAIL

Fan speed too low or fan off
The smoke fan is blocked.

Check for cleanliness and whether the is slowing the fan.

If cleaning does not solve the problem, repalce the

smoke fan

ALAR SMOKE PROBE Smoke sensor short circuit

Replace smoke sensor

ALAR SAFE FAIL

The safety has tripped that controls the pellet hopper.

Overheating has occurred due to a malfunction

Check the parameters of the recipe used.

Heat exchanger not working.

The stove is used for too long at maximum operating

power.

ALAR HOT TEMP

This occurs when the smoke temperature exceeds 180°

for an excessive length of time.

Clean the inside of the heat exchanger and run the stove

at full power for shorter periods of time. Also check the

quality of the pellets.

ALAR NO ACC

Occurs on first failed attempt at lighting

If this is the first attempt at lighting, relight or check the

level of pellets in the hopper.
Check the ignition plug.

ALAR NO FIRE

Occurs when the stove goes out and when the

temperature of the smoke sensor is below the preset

threshold.

It is caused when the flame is extinguished due to

clogging or when there are no longer any pellets in the

hopper.


ALLAR

TEMP.PELLET

Pellet hopper temperature exceeds foreseen safety limit.
Overheating of the stove body.

The stove body is too hot because the product has been

operating for too long at maximum power, it is poorly

ventilated or the air fans are faulty. Shut down the stove

by pressing key 5 on the control panel, and wait for it to

cool. After it has cooled down, the stove can be relit.