Theoretical notions for installation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

Ispezione

Condott o

esterno

isolato

0,5 mt.

3 -5 %

2 - 3 mt. MA X

M

in

im

o 1

,5

- 2

m

t.

Is pezione

0,5 m t.

Ca nna fumaria

Comignolo

a ntivento

2.6. CONNECTION TO THE FLUE PIPE

The flue pipe must have internal dimensions not larger than 20 x 20

cm, or diameter 20 cm. In the event of larger dimensions, or of the flue

pipe being in poor condition (for example cracks, poor insulation, etc.),

it is advisable to fit a stainless steel pipe of suitable diameter inside the

flue pipe throughout its length, right up to the top.

Figure 9

Check with suitable instruments that there is a minimum draught of 10 Pa.
At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.
Make a gas-tight connection to the flue pipe, using pipes and

connectors as recommended by us.
You must ensure that a windproof cowl is fitted which complies with

current standards.

This type of connection ensures the evacuation of the

fumes even in the event of a temporary power

outage.

2.7. CONNECTION TO AN EXTERNAL FLUE WITH

INSULATED OR DOUBLE-WALL PIPE

The external fluepipe must have internal dimensions of minimum 10x10

cm or 10 cm diameter, and maximum 20x20 cm or 20 cm diameter.
Check with suitable instruments that there is a minimum draught of 10 Pa.

Figure 10
The only type of pipe which is permissible is insulated (double-walled)

stainless steel, smooth on the inside, fixed to the wall. Flexible stainless

steel pipe must not be used.
At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.
Make a gas-tight connection to the flue pipe, using pipes and

connectors as recommended by us.
You must ensure that a windproof cowl should be fitted which complies

with the standards in force.

This type of connection ensures the evacuation of the

fumes even in the event of a temporary power cut.

2.8. CONNECTION TO FLUE PIPE OR SMOKE DUCT

For proper operation, the connection between the stove and the flue

pipe or smoke duct must have a slope of not more than 3%. The length

of the horizontal segment must not exceed 2/3 m. and the vertical

distance between one tee connector and another (change of direction)

must not be less than 1.5m.
Check with suitable instruments that there is a minimum draught of 10 Pa.

Figure 11
At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.

Figure 9

Figure 10

Figure 11

Canna fumar ia

Comignolo

antivento

Ispezione

0,5 mt.

Windproof

cowl

Flue pipe

Inspection

cover

Inspection

cover

Insulated

external pipe

Inspection

cover

Flue pipe

Windproof

cowl