Ut 20 off, Setting of eco-stop mode – MCZ Athos HYDRO 14 kW User Manual

Page 41

background image

PELLET STOVES

Chapter 4

INSTALLATION AND USE MANUAL

page

41

Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

4.10.2.1. Internal thermostat - Position of internal room sensor

Only when installation is complete, be sure to check that the

room probe is removed from its place and set far away from

the stove, to prevent it from detecting incorrect temperatures.
The probe is located on the back part of the stove.
When you use the internal thermostat, you should always set a

temperature that is a few degrees higher (for example, if you want to

attain 20°C you should set to 22°C) because the probe is affected by

the heat from the body of the stove.

4.10.2.2. Operation by means of external thermostat

EXTERNAL THERMOSTAT (not included with the stove, to be

provided by the user)
The temperature of the stove can also be controlled by an external

room thermostat. It is located in a central position of the room where

the stove is installed. It provides a closer match between the heating

temperature requested of the stove and what it actually provides.

4.10.2.3. Connection of external thermostat

Connect the two wires coming from the wall-mounted thermostat to the

terminal of the MCZ connector.
Insert the connector in the socket located on the back of the stove.

Figure 7

Once the thermostat is connected, you will need to

disconnect the internal thermostat that the stove is

equipped with.

In order to do this, proceed as follows:

Press the button

o

immediately followed by the button

p

on the

control panel. The display of the control panel will show the

message UT01/OFF

Press the button

p

repeatedly until the display on the panel shows

UT16"; the display of the control panel shows UT16

Press and hold the button

q

and then press the button

p

and go

to item

“UT20”; the display will show the message UT19/OFF

Using the buttons

n

or

o

, set this parameter to “ON” or “OFF”. If

it is set to “ON”, the internal thermostat is enabled. Conversely, if it

the parameter is set to “OFF”, the external thermostat is enabled

and the internal one is disabled.

Therefore, if you need to enable the external thermostat, you will

need to set parameter “UT20” to “OFF”.

To exit the menu, press the button

r

or wait 60 seconds

4.10.3. Setting of ECO-STOP mode

The thermostat manages stove operation by shutting the stove

down once the set temperature is reached and then lighting

again when this is necessary.
You can activate or de-activate this function, or select the intervals with

which the stove is to shut down.

Figure 7 - Connection of the serial connector of the

serial connector of the external thermostat in the socket

on the back of the stove

SET

TUR BO

1

2

6

4

3

5

!

Ut 20

OFF

External thermostat enabled and internal thermostat

disabled

Internal room probe

Wiring from

external thermostat

MCZ serial

connector