BULB TEMPERATURE PROBE IN THE WATER TANK

If the temperature exceeds the preset safety level, it immediately

shuts down the running of the stove, and has to be reset manually

before the stove will restart

(see paragraph 4.20.3).

WATER TEMPERATURE PROBE

If the temperature of the water approached shutdown temperature

(85°C), the probe causes the stove to go through a series of

cooling cycles or “ECO-STOP” automatic shutdown to prevent

blocking of the bulb temperature probe as described above.

ELECTRICAL SAFETY

The stove is protected against violent surges of current by the

main fuse, which is located on the control panel at the rear of the

stove. Other fuses to protect the electronic boards (main board

and heat-exchanger board) are to be found on the boards

themselves.

SMOKE FAN

If the fan stops, the electronic board shuts off the supply of pellets

in good time, and an alarm message is displayed.

REDUCTION MOTOR

If the reduction motor stops, the stove will continue to run until

the flame goes out due to lack of fuel and until a minimum level of

cooling is reached.

TEMPORARY POWER OUTAGE

After a brief power outage, it automatically goes into cooling

mode.

FAILURE TO LIGHT

If during ignition no flame develops, the stove will go into alarm

condition.

ANTI-FREEZE FUNCTION

If the probe in the boiler detects a water temperature of less than

5°C, the circulation pump is automatically activated to keep teh

system from freezing.

PUMP ANTI-SEIZURE FUNCTION

If the pump is not used for prolonged periods, it is activated

periodically for 10 seconds to keep it from seizing up.

TAMPERING WITH THE SAFETY DEVICES IS

PROHIBITED
Only after eliminating the cause of the intervention of the

safety is it possible to relight the stove and thus restore its

operation. To understand which anomaly has occurred,

consult this manual

(paragraph 4.10.1) which explains what

to do based on the alarm message the stove displays.


This manual is related to the following products: