3.3.5. Installation of ceramic top
Install the top by setting it on the four upper protuberances of the
stove. The part underneath is provided with four small cavities at the
rubber supports indicated in
figure 11.
3.4. PLUMBING SYSTEM CONNECTION
IMPORTANT!
The connection of the stove to the plumbing system
must be made ONLY by specialized personnel who
are capable of carrying out installation properly, in
compliance with current standards in the country of
installation.
MCZ will not be held responsible for damage to
persons or things in the event of failed operation if
the aforementioned warning is not complied with.
Connect the stove using the connections provided in the lower rear part
of the unit
CONNECTION DIAGRAM FOR POLAR/NOVA STOVE WITHOUT KIT FOR PRODUCTION OF DOMESTIC
HOT WATER
192
275
3
3
4
2
8
1
Ш80
Ш48
140
255
122
1
8
5
2
4
0
140
3
0
D
E
A1
C
A2
CONNECTION DIAGRAM FOR POLAR/NOVA STOVE WITH KIT FOR PRODUCTION OF DOMESTIC HOT
WATER
192
275
3
3
4
2
8
1
Ш80
Ш48
140
65
97
75
192
1
8
5
2
4
0
3
0
140
D
E
A1
B1
C
B2 A2
Figure 11 – Supports for installation of
ceramic top
A1=Heating water delivery 3/4”M
A2=Heating water return 3/4”M
C=Vent 3/4”M
D=Refill 3/8”M
E= System empting and discharge 3/4”M
A1=Heating water delivery 3/4”M
A2=Heating water return 3/4”M
B1=Domestic hotwater outlet 1/2”M
B2=Domestic hotwater inlet 1/2”M
C=Vent 3/4”M
D=Refill 3/8”M
E= System empting and discharge 3/4”M