3.3.5. Installation of ceramic top

Install the top by setting it on the four upper protuberances of the

stove. The part underneath is provided with four small cavities at the

rubber supports indicated in

figure 11.

3.4. PLUMBING SYSTEM CONNECTION

IMPORTANT!

The connection of the stove to the plumbing system

must be made ONLY by specialized personnel who

are capable of carrying out installation properly, in

compliance with current standards in the country of

installation.

MCZ will not be held responsible for damage to

persons or things in the event of failed operation if

the aforementioned warning is not complied with.

Connect the stove using the connections provided in the lower rear part

of the unit

CONNECTION DIAGRAM FOR POLAR/NOVA STOVE WITHOUT KIT FOR PRODUCTION OF DOMESTIC

HOT WATER

192

275

3

3

4

2

8

1

Ш80

Ш48

140

255

122

1

8

5

2

4

0

140

3

0

D

E

A1

C

A2

CONNECTION DIAGRAM FOR POLAR/NOVA STOVE WITH KIT FOR PRODUCTION OF DOMESTIC HOT

WATER

192

275

3

3

4

2

8

1

Ш80

Ш48

140

65

97

75

192

1

8

5

2

4

0

3

0

140

D
E

A1
B1

C

B2 A2

Figure 11 – Supports for installation of

ceramic top

A1=Heating water delivery 3/4”M
A2=Heating water return 3/4”M
C=Vent 3/4”M
D=Refill 3/8”M
E= System empting and discharge 3/4”M

A1=Heating water delivery 3/4”M
A2=Heating water return 3/4”M
B1=Domestic hotwater outlet 1/2”M
B2=Domestic hotwater inlet 1/2”M
C=Vent 3/4”M
D=Refill 3/8”M
E= System empting and discharge 3/4”M