2-12 / Installation & Operation

CI-ControlWave EFM

by cathodic protection or other EMF on the pipeline. ControlWave EFMs may be mounted
directly on the pipeline (see Figure 2-6) or remotely on a vertical stand-alone two-inch pipe
(see Figure 2-7). It is recommended that isolation fitting always be used in remotely
mounted meter systems. An isolation fittings or gasket should be installed between the
following connections:

• all conductive tubing that runs between the pipeline and mounting valve manifold

and/or the units Multivariable Transducer (MVT)

• all conductive connections or tubing runs between the ControlWave EFM electronic

flow meter and a turbine meter, pulse transducer, or any other I/O device that is
mounted on the pipeline

• any Temperature Transducer, Pressure Transmitter, etc. and their mount/interface to

the pipeline.

Isolating

Fittings

Clamp(s)

Ground Rod or System

AWG 4 Ground Wire

2” Pipe-mounting Package

Mounting Pipe does not
contact the Main Pipeline.

Note:

Mounting Bolts (4)

Bottom Washers (4)

Top Washers (4)

Dielectric Bolt Sleeves (4)

Dielectric Gasket

& Flange Seals (2)

Multivariable

Transducer

(MVT)

Valve Block

Manifold

Transducer to Manifold

Dielectric Isolation Kit

Figure 2-7 - ControlWave EFM Remote Installation

(with Cathodic Protection)


Note: Remote installation of a unit, without Cathodic protection, is similar to that
of Figure 2-7 except it doesn’t utilize the Transducer to Manifold Dielectric
Isolation Kit.

Mount the ControlWave EFM’s enclosure on a stand-alone vertical 2-inch pipe or on a
wall. The ground conductor connects between the ControlWave EFM’s Chassis Ground
Lug and a known good earth ground. Connect the cases of Temperature Transducers,
Pressure Transmitters, etc., to the known good earth ground. If the mounting 2-inch pipe
(when used) is in continuity with the pipeline it will have to be electrically isolated from the
ControlWave EFM. Use a strong heat-shrink material such as RAYCHEM WCSM 68/22
EU 3140. This black tubing will easily slip over the 2-inch pipe and then after uniform