©2013 Magnum Energy, Inc.

35

5.0 Operation

LED

Status

Meaning

INV

(green)

OFF

1. Inverter is disabled; or 2. Remote is in Power

Saver mode – press any button to activate LEDs.

ON

Inverter is enabled – 1. Supplying AC power on

the output; or 2. In Standby (a charge status

displays); the inverter will automatically supply

AC power to the loads if shore or generator

power is lost.

BLINKING

Inverter is in Search mode (the AC load is below

the Search Watts setting).

FAULT

(red)

OFF

Normal operation.

ON

A fault condition has been detected, check the

LCD display to fi nd and correct the cause.

5.3.4 LED Indicator Guide

The remote provides the following LED statuses. Use them along with the LCD

display to determine the inverter/charger’s operating status.

Table 5-1, LED Indicator Guide

IntRelay appears on the LCD and

the FAULT (red) LED is on. The INV

(green) LED is off.

FAULT !
IntRelay

Figure 5-37, Internal Relay Fault

• Internal

Relay

Fault – The internal transfer relay is not closing even

though the inverter is in Charge mode. Contact Magnum Technical Support

(425-353-8833) for assistance.