5

3.0 Setup

3.0 Setup

When the ME-MR remote is connected to a Magnum inverter/charger, the

remote’s settings determine the inverter/charger’s operating parameters.

The default settings in the remote (see Table 3-4) are adequate for most

installations. However, you can change some of the operating parameters if

needed. This section shows you how to navigate the remote, and gives you

an understanding of the function of each adjustable setting.

3.1

Navigating the Remote

The ME-MR has menu items and adjustable settings that provide the ability to

confi gure your inverter/charger to your specifi c parameters.

Info: See Figure 4-1 for a complete map of the remote’s menu

items and adjustable settings.

The items on the remote’s front panel are used to fi nd, adjust, and save the

desired setting. They are:
• LCD

Display

The LCD display shows menu items, adjustable settings,

and the meter’s display information.

Info: The LCD display returns to the scrolling Home screens to show

inverter status, DC voltage and current, and any fault present (if ap-

plicable) after 30 seconds—if no buttons have been pressed.
Info: When the ”” (left facing arrow) symbol is shown on the

display, it indicates that the displayed setting has been selected

and will be used.

• ON/OFF/CHANGE

Button

Allows you to quickly scroll through and

select various menu items and settings after pressing the MENU button.

• MENU/HOME

Button

Allows easy access to the menu items that can

help with confi guring, monitoring, and troubleshooting your inverter/

charger. Press and hold this button (2 seconds) to return to the scrolling

Home screens (Figure 3-1).

• SAVE/HOLD

Button

Saves the menu item displayed on the screen. A

saved setting is denoted by the arrow symbol. Press and hold this button

(2 seconds) to stop the Home screens from scrolling (“HOLD” displays).

Press once to view the next Home screen. Press and hold again (2 sec-

onds) to resume scrolling of the Home screens (“SCROLL” displays).

STATUS

Invert

FAULT !

Low Batt

BATTERY

11.4V

BATTERY

- 0A

Note: Fault screen only appears if a fault has been detected

Battery Voltage

Battery Current

Inverter/Charger

Status

Inverter/Charger

Fault

Figure 3-1, Scrolling Home Screens