16

©2013 Magnum Energy, Inc.

3.0 Setup

3.2.12 TECH Menu

• TECH – This menu provides access to read only system information

that can assist service technicians in troubleshooting. It also offers a

selection that enables you to return all system settings to the original

factory default values, and another that locks some setup menus.

Scroll to the end of the remote’s menus until “TECH, Press ON” appears. Press

the ON/OFF CHANGE button to access these selections. Continue to press the

ON/OFF CHANGE button to view each TECH menu item.

Bat Temp: Displays the temperature of the battery temperature sensor

(BTS)—if connected.

Xfm Temp: Displays the temperature of the inverter’s transformer.

FET Temp: Displays the temperature of the FETs (Field Effect Transistors).

Inverter Rev: Displays the fi rmware revision level of the inverter.

Remote Rev: Displays the fi rmware revision level of the remote.

Model: Displays the model number of the connected inverter.

Info: If “Model Unknown” displays, the remote is unable to determine

the inverter model. This may be due to an inverter revision newer

than the remote. All remote menu selections/features that are avail-

able in the inverter will function normally.

Ext Ctrl: Magnum has an open protocol policy that allows certain functions

(AC In, Charge Rate, & VAC Dropout settings) of the inverter/charger to be

controlled externally—such as with a third party communications device.
No – there is no external device controlling any of the inverter’s settings.
INT – an external device is controlling the setting—however, the

external device has not changed the setting at this time.
EXT – an external device is controlling the setting—and, the external

device has changed the setting.
When an external device is connected, the above menus scroll across the

bottom line of the display. The INT or EXT display denotes whether the

setting has been changed. Example:

AC IN INT...CHR% INT...VAC EXT.

An external device is connected, the

AC IN and Charge Rate settings

have not been changed, but the VAC Dropout setting has been changed.

SETUP: Allows you to Lock or Unlock the setup menus on your remote.

Press the SAVE/HOLD button to select to lock the setup menus (Lock) or

to unlock (Unlock) the setup menus.
Note: Exception - AC In menu does not lock.

Bottom line shows

current “saved” setting

If this setting is correct,

press MENU button to

access different menu items

If a different setting

is required:

press

press

press

To save the current

setting displayed:

ON/OFF

CHANGE

MENU

HOME

SAVE

HOLD

POWER ON

Norm

POWER ON

Always

POWER ON

Norm

Figure 3-12, Power On Selections