3.2.10 Charger Standby Menu

• CHARGER

Select whether to activate Charger Standby mode after

AC power is connected (charger ready and waiting for AC input).
Default setting: CHARGER = No AC In
Range: No AC In, Chg Stby

What is Charger Standby? When the charger is in Charger Standby, the

incoming AC is still available on the inverter’s output, but the charger is not

allowed to charge.

Info: To resume charging, access the Charger Standby menu and

press the CHANGE button.

Info: If upon accessing this menu “No AC In” displays, you will not be

able to change the Charger’s status.

Bottom line shows

current charger status

This status will not change

until AC is connected

If a different status

is required:

press

press to change status

ON/OFF

CHANGE

MENU

HOME

CHARGER

Absorb

CHARGER

Status

CHARGER

Chg Stby

Possible statuses:

Absorb, Bulk, Charging, Equalizing (EQing), Float, Full Charge

(Full Chg), Load Support AAC (LS AAC), Load Support VDC (LS VDC)

Figure 3-11, Charger Standby Selections

3.2.11 Power On Menu

• POWER

ON – Select whether to have the inverter power up and provide

AC power automatically once DC voltage is connected to it.
Default: POWER ON = Norm
Range: Norm (Normal), Always

What is the Power On feature? Normally, when DC power is connected

to the inverter, the user is required to press the power button—on the

inverter or remote—to turn the inverter on (Norm). When the Power On

feature is activated by selecting Always, the inverter is automatically turned

on and starts searching or inverting—depending on the Search Watts setting

(see Section 3.2.2). Once the inverter has connected to DC power and is

automatically turned on, the power button—on the inverter or remote—can

be used to turn the inverter on or off.
Why use the Power On feature? Some customers are familiar with

Uninterruptible Power Supplies (UPS) that power-up automatically when DC

power is connected. The Power On feature can be used by customers that

want to obtain the same automatic power-up feature with which they are

familiar.