3.4 I/O Signal Allocations

3-27

3

Wi

ring and

C

onne

ctio

n

∗1. For details, refer to the manual of the connected command option module.

∗2. These pins cannot be used.

Note: The factory settings of the parameters in a large-capacity

Σ-V SERVOPACK are not all the same as those for a stan-

dard

Σ-V SERVOPACK. Make sure that you consider any differences in the factory settings if you copy the param-

eters from a standard

Σ-V SERVOPACK to a large-capacity Σ-V SERVOPACK.

3.4.2 Output Signal Allocations

Output signals are allocated as shown in the following table.

Refer to the Interpreting the Output Signal Allocation Tables and change the allocations accordingly.

Forward External

Torque Limit

Pn50B.2

L

/P-CL

0

1

2

3

4

5

6

7

8

H

P-CL

9

A

B

C

D

E

F

Reserve External

Torque Limit

Pn50B.3

L

/N-CL

0

1

2

3

4

5

6

7

8

H

N-CL

9

A

B

C

D

E

F

Command Option
Module Input 1

*1

Pn511.0

L

/SI1

0

1

2

3

4

5

6

7

8

H

SI1

9

A

B

C

D

E

F

Command Option
Module Input 4

*1

Pn511.1

L

/SI4

*2

*2

*2

*2

4

5

6

7

8

H

SI4

*2

*2

*2

*2

D

E

F

Command Option
Module Input 5

*1

Pn511.2

L

/SI5

*2

*2

*2

*2

4

5

6

7

8

H

SI5

*2

*2

*2

*2

D

E

F

Command Option
Module Input 6

*1

Pn511.3

L

/SI6

*2

*2

*2

*2

4

5

6

7

8

H

SI6

*2

*2

*2

*2

D

E

F

DB Answer

Pn515.2

L

/DBANS

0

1

2

3

4

5

6

7

8

H

DBANS

9

A

B

C

D

E

F

(cont’d)

Input Signal Names

and Parameters

Validity

Level

Input

Signal

CN1 Pin Numbers

Connection Not

Required

(SERVOPACK

judges the

connection)

40

41

42

43

44

45

46

Always

ON

Always

OFF

• The signals not detected are considered as "Invalid." For example, Positioning Com-

pletion (/COIN) signal in speed control is "Invalid."

• Inverting the polarity of the brake signal (/BK), i.e. positive logic, will prevent the hold-

ing brake from working in case of its signal line disconnection.
If this setting is absolutely necessary, check the operation and confirm that there are
no safety problems.

• When two or more signals are allocated to the same output circuit, a signal is output

with OR logic circuit.