Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Command Option Interface User Manual
Page 333
10 Appendix
10.1.2 Parameters
10-4
Pn002
2
Application Function Select Switch 2
0000 to 4113
−
0000
After restart
Setup
−
∗1. For details on this function, refer to the manual of the connected command option module.
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
∗The mode will be switched to semi-closed position control if Pn002.3 is set to 0.
Torque Limit Reference Selection for Command Option Module
*1
0
Disables the torque limit reference from the command option module.
1
Enables the torque limit reference from the command option module.
2
Reserved (Do not change.)
3
Enables torque limit reference from the command option module when external input signals P-CL
and N-CL are enabled.
Speed Limit Reference Selection for Command Option Module
*1
0
Disables the speed limit reference when torque limit is used from the command option module.
1
Enables the speed limit reference when torque limit is used from the command option module.
Absolute Encoder Usage
Reference
Section
0
Uses absolute encoder as an absolute encoder.
4.5
1
Uses absolute encoder as an incremental encoder.
External Encoder Usage
Reference
Section
0
Do not use external encoder.
*
8.3.1
1
Uses external encoder in standard rotation direction.
2
Reserved (Do not set.)
3
Uses external encoder in reverse rotation direction.
4
Reserved (Do not set.)
4th 3rd 2nd 1st
digit digit digit digit
n.