10 Appendix
10.1.2 Parameters
10-14
Pn404
2
Forward External Torque Limit
0 to 800
1%
100
Immediately
Setup
4.4.2
Pn405
2
Reverse External Torque Limit
0 to 800
1%
100
Immediately
Setup
4.4.2
Pn406
2
Emergency Stop Torque
0 to 800
1%
800
Immediately
Setup
4.2.3
Pn407
2
Speed Limit during Torque Control
0 to 10000
1 min
-1
10000
Immediately
Setup
4.6.8
Pn408
2
Torque Related
Function Switch
0000 to 1111
−
0000
−
−
−
Pn409
2
1st Notch Filter Frequency
50 to 5000
1 Hz
5000
Immediately
Tuning
5.9.3
Pn40A
2
1st Notch Filter Q Value
50 to 1000
0.01
70
Immediately
Tuning
5.9.3
Pn40B
2
1st Notch Filter Depth
0 to 1000
0.001
0
Immediately
Tuning
5.9.3
Pn40C
2
2nd Notch Filter Frequency
50 to 5000
1 Hz
5000
Immediately
Tuning
5.9.3
Pn40D
2
2nd Notch Filter Q Value
50 to 1000
0.01
70
Immediately
Tuning
5.9.3
Pn40E
2
2nd Notch Filter Depth
0 to 1000
0.001
0
Immediately
Tuning
5.9.3
Pn40F
2
2nd Step 2nd Torque Reference Filter
Frequency
100 to 5000
1 Hz
5000
Immediately
Tuning
5.9.3
Pn410
2
2nd Step 2nd Torque Reference Filter Q
Value
50 to 100
0.01
50
Immediately
Tuning
5.9.3
Pn412
2
1st Step 2nd Torque Reference Filter
Time
Constant
0 to 65535
0.01 ms
100
Immediately
Tuning
5.8.1
Pn415
2
Reserved (Do not change.)
−
−
0
−
−
−
Pn423
2
Reserved (Do not change.)
−
−
0000
−
−
−
Pn424
2
Torque Limit at Main Circuit Voltage
Drop
0 to 100
1%
50
Immediately
Setup
4.2.10
Pn425
2
Release Time for Torque Limit at Main
Circuit Voltage Drop
0 to 1000
1 ms
100
Immediately
Setup
4.2.10
Pn456
2
Sweep Torque Reference Amplitude
1 to 800
1%
15
Immediately
Tuning
6.21
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
1st Step Notch Filter Selection
When
Enabled
Classification
Reference
Section
0
N/A
Immediately
Setup
5.9.3
1
Uses 1st step notch filter for torque reference.
Speed Limit Selection
When
Enabled
Classification
Reference
Section
0
Uses the smaller of the maximum motor speed and
the value of Pn407 as the speed limit value.
After restart
Setup
4.6.8
1
Uses the smaller of the overspeed detection speed
and the value of Pn407 as the speed limit value.
2nd Step Notch Filter Selection
When
Enabled
Classification
Reference
Section
0
N/A
Immediately
Setup
5.9.3
1
Uses 2nd step notch filter for torque reference.
Friction Compensation Function Selection
When
Enabled
Classification
Reference
Section
0
Disables friction compensation function.
Immediately
Setup
5.8.2
1
Enables friction compensation function.
4th 3rd 2nd 1st
digit digit digit digit
n.