9 Troubleshooting
9.1.1 List of Alarms
9-4
A.b31
Current Detection Error 1
The current detection circuit for phase U is faulty.
Gr.1
N/A
A.b32
Current Detection Error 2
The current detection circuit for phase V is faulty.
Gr.1
N/A
A.b33
Current Detection Error 3
The detection circuit for the current is faulty.
Gr.1
N/A
A.bF0
System Alarm 0
"Internal program error 0" of the SERVOPACK occurred.
Gr.1
N/A
A.bF1
System Alarm 1
"Internal program error 1" of the SERVOPACK occurred.
Gr.1
N/A
A.bF2
System Alarm 2
"Internal program error 2" of the SERVOPACK occurred.
Gr.1
N/A
A.bF3
System Alarm 3
"Internal program error 3" of the SERVOPACK occurred.
Gr.1
N/A
A.bF4
System Alarm 4
"Internal program error 4" of the SERVOPACK occurred.
Gr.1
N/A
A.C10
Servo Overrun Detected
The servomotor ran out of control.
Gr.1
Available
A.C80
Absolute Encoder Clear
Error and Multiturn Limit
Setting Error
The multiturn for the absolute encoder was not properly cleared or
set.
Gr.1
N/A
A.C90
Encoder Communications
Error
Communications between the SERVOPACK and the encoder is not
possible.
Gr.1
N/A
A.C91
Encoder Communications
Position Data Error
An encoder position data calculation error occurred.
Gr.1
N/A
A.C92
Encoder Communications
Timer Error
An error occurs in the communications timer between the encoder
and the SERVOPACK.
Gr.1
N/A
A.CA0
Encoder Parameter Error
Encoder parameters are faulty.
Gr.1
N/A
A.Cb0
Encoder Echoback Error
Contents of communications with encoder are incorrect.
Gr.1
N/A
A.CC0
Multiturn Limit
Disagreement
Different multiturn limits have been set in the encoder and the SER-
VOPACK.
Gr.1
N/A
A.CF1
Feedback Option Module
Communications Error
(Reception error)
Reception from the Feedback Option Module is faulty.
Gr.1
N/A
A.CF2
Feedback Option Module
Communications Error
(Timer stop)
Timer for communications with the Feedback Option Module is
faulty.
Gr.1
N/A
A.d00
Position Error Overflow
Position error exceeded the value of excessive position error alarm
level (Pn520) when the servomotor power is ON.
Gr.1
Available
A.d01
Position Error Overflow
Alarm at Servo ON
This alarm occurs if the servomotor power is turned ON when the
position error is greater than the set value of Pn526 while the servo-
motor power is OFF.
Gr.1
Available
A.d02
Position Error Overflow
Alarm by Speed Limit at
Servo ON
When the position errors remain in the error counter, Pn529 limits
the speed if the servomotor power is turned ON. If Pn529 limits the
speed in such a state, this alarm occurs when position references are
input and the number of position errors exceeds the value set for the
excessive position error alarm level (Pn520).
Gr.2
Available
A.d10
Motor-load Position Error
Overflow
During fully-closed loop control, the position error between motor
and load is excessive.
Gr.2
Available
A.E00
Command Option Module
IF Initialization Timeout
Error
Communications initialization failed between the SERVOPACK
and the command option module.
Gr.2
Available
A.E02
Command Option Module
IF Synchronization Error 1
A synchronization error occurred between the SERVOPACK and
the command option module.
Gr.1
Available
A.E03
Command Option Module
IF Communications Data
Error
An error occurred in the data of communications between the SER-
VOPACK and the command option module.
Gr.1
Available
A.E40
Command Option Module
IF Communications Setting
Error
An error occurred in establishing communications (settings)
between the SERVOPACK and the command option module.
Gr.2
Available
A.E50
Command Option Module
IF Synchronization Error 2
A error occurred in synchronization between the SERVOPACK and
the command option module.
Gr.2
Available
(cont’d)
Alarm
Number
Alarm Name
Meaning
Servomotor
Stopping
Method
Alarm
Reset