10 Appendix 2 Parameter Cross Reference

52

YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide

Multi-Function Relay
Output

Multi Function Input
(terminal 25-27)
(terminal M3-M4 for
A1000)

H2-02

1

H2-02

1

12: Timer function output

12: Timer function output

13: Frequency agree 2

13: Frequency agree 2

14: User-Set frequency agree 2

14: User-Set frequency agree 2

15: Frequency detection 3

15: Frequency detection 3

16: Frequency detection 4

16: Frequency detection 4

17: Torque detection 1 (N.C.)

17: Torque detection 1 (N.C.)

18: Torque detection 2 (N.O.)

18: Torque detection 2 (N.O.)

19: Torque detection 2 (N.C.)

19: Torque detection 2 (N.C.)

1A: Reverse run

1A: Reverse run

1B: During baseblock 2 (N.C.)

1B: During baseblock 2 (N.C.)

1C: Motor selection

1C: Motor selection

1D: Regenerating during run

1D: Regeneration during run

1E: Fault restart

1E: Fault restart

1F: Motor overload alarm

1F: Motor overload alarm

20: Drive overheat alarm

20: Drive overheat alarm

22: Mechanical weakening
(N.O.)

2F: Maintenance timer

30: During torque limit

30: During torque limit

31: During speed limit

31: During speed limit

Multi-function input
(terminal 26-27)
(terminal M5-M6 for
A1000)

H2-03

2

H2-03

2

32: Speed Limit Circuit During
Run

33: Zero servo complete

33: Zero servo complete

37: During run 2

37: During frequency output

38: Drive enabled

39: Kilowatt hour output

3C: Operation mode

3D: Speed Search

3E: PID feedback fault (during
loss )

3F: PID feedback too high
(fault)

4A: During KEB

4B: During Short Braking

4C: During Fast Stop

4D: oH pre-alarm time limit

4E: During Rr

4F: During Rh

60: Internal Cooling fan fault

61: Pole detection complete

90 to 92: DriveWorksEZ,
outputs 1-3

100 to 192: Reverse Output of
0-92

Analog Input

Signal level selection
(terminal 13) (terminal
A1 for A1000)

H3-01

0

H3-01

0

In A1000, terminal A1 is multi-functional input terminal.

H3-01

H3-01

0: 0 to +10 V

0: 0 to +10 V (uses lower limit)

1: -10 to 10 V

1: 0 to ±10 V (no lower limit)

Terminal A1 Function
Selection

H3-02

0

Parameter H3-02 should be set to 0 in A1000.

Gain (terminal 13)
(terminal A1 for
A1000)

H3-02

100.0 %

H3-03

100.0 %

F2-02

100.0 %

Set this parameter when using an analog option card to determine
the bias for the analog reference.

Parameter Name

G5

A1000

Comments (Gray shading indicates default settings)

No.

Default

No.

Default

G5

A1000