10 Appendix 2 Parameter Cross Reference
42
YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide
Carrier Frequency
Carrier Frequency
Upper Limit
C6-01
10.0 kHz
C6-02
*
* Default setting is determined by the control mode and by drive
capacity. Change the setting for C6-02 to F.
C6-03
2.0 kHz
─
Carrier Frequency
Lower Limit
C6-02
10.0 kHz
C6-02
*
* Default setting is determined by the control mode and by drive
capacity. Change the setting for C6-02 = F.
C6-04
2.0 kHz
─
Carrier Frequency
Proportional Gain
C6-03
00
C6-05
0
─
Hunting Prevention
Function
Hunting prevention
function selection*
C7-01
1
N1-01
1
* These parameters are only displayed when using V/f Control of
with PG.
C7-01
n1-01
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Hunting Prevention
Gain *
C7-02
1.00
n1-02
1.00
* These parameter are only displayed when using V/f Control of
V/f Control with PG.
Factory Tuning
Parameters
Carrier frequency
selection during
autotuning
C8-30
2
C6-09
0
C8-30
C6-09
0: 2 kHz
1: Setting value of C6-03*
1: Setting value of C6-01
1: Setting value of C6-03*
2: 5 kHz
0: 5 kHz
*Auto-Tuning set C6-09 tp va;ie pf C6-03.
Frequency Reference
Frequency Reference 1
d1-01
0.00 Hz
d1-01
0.00 Hz
─
Frequency Reference 2
d1-02
0.00 Hz
d1-02
0.00 Hz
─
Frequency Reference 3
d1-03
0.00 Hz
d1-03
0.00 Hz
─
Frequency Reference 4
d1-04
0.00 Hz
d1-04
0.00 Hz
─
Frequency Reference 5
d1-05
0.00 Hz
d1-05
0.00 Hz
─
Frequency Reference 6
d1-06
0.00 Hz
d1-06
0.00 Hz
─
Frequency Reference 7
d1-07
0.00 Hz
d1-07
0.00 Hz
─
Frequency Reference 8
d1-08
0.00 Hz
d1-08
0.00 Hz
─
Jog Frequency
Reference 9
d1-09
6.00 Hz
d1-09
0.00 Hz
─
Frequency Limits
Frequency Reference
Upper Limit Value
d2-01
100.0 %
d2-01
100.0 %
─
Frequency Reference
Lower Limit Value
d2-02
0.0 %
d2-02
0.0 %
─
Setting Prohibited
Frequency
Jump Frequency 1
d3-01
0.0 Hz
d3-01
0.0 Hz
─
Jump Frequency 2
d3-02
0.0 Hz
d3-02
0.0 Hz
─
Jump Frequency 3
d3-03
0.0 Hz
d3-03
0.0 Hz
─
Jump Frequency Width
d3-04
1.0 Hz
d3-04
1.0 Hz
─
Frequency Reference
Hold
Frequency Reference
Hold Function
Selection
d4-01
0
d4-01
0
d4-01
d4-01
0: Disabled
0: Disabled
1: Enabled
1: Enabled
+/- Speed limit
d4-02
10 %
d7-01
0.0 %
d4-02
d7-01
d7-02
d7-02
0.0 %
Set value
Set value
No need to set
No need to set
Negative
Torque Control
Torque Control
Selection
d5-01
0
d5-01
0
d5-01
d5-01
0: Speed Control
0: Speed Control
1: Torque Control
1: Torque Control
Frequency reference
hold function selection
d5-02
0 ms
d5-02
0 ms
─
Speed Limit Selection
d5-03
1
d5-03
1
d5-03
d5-03
1: Limited by b1-01
1: Limited by b1-01
2: Limited by d5-04
2: Limited by d5-04
Speed Limit
d5-04
0 %
d5-04
0 %
─
Speed Limit Bias
d5-05
10 %
d5-05
10 %
─
Speed/Torque Control
Switch Timer
d5-06
0 ms
d5-06
0 ms
─
Parameter Name
G5
A1000
Comments (Gray shading indicates default settings)
No.
Default
No.
Default
G5
A1000