10 appendix 2 parameter cross reference, Parameter compatibility table, Appendix 2 parameter cross reference – Yaskawa GPD515/G5 User Manual
Page 38: Parameter compatibility table 1, Table 23 parameter cross reference

38
YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide
10 Appendix 2 Parameter Cross Reference
10
Appendix 2 Parameter Cross Reference
Parameter Compatibility Table
1.
This document lists the information needed to upgrade from G5 to a new A1000 drive. The A1000 drive must be set for Heavy Duty. First, set A1000
parameter C6-01 to 0.
2.
Check all G5 parameters that have been changed from their default settings by using the Modified Constants Menu.
3.
Set the same control mode used for G5 to A1000.
4.
Set parameters as described in this section.
Note: Default Values in the table below are listed for A1000 240 V Class 0.4 kW Drive Using Open Loop Vector Control.
Table 23 Parameter Cross Reference
Parameter Name
G5
A1000
Comments (Gray shading indicates default settings)
No.
Default
No.
Default
G5
A1000
Environment Settings
Language Selection for
digital operator display
A1-00
0
A1-00
0
A1-00
A1-00
0: English
0: English
1: Japanese
1: Japanese
2: German
2: German
3: French
3: French
4: Italian
4: Italian
5: Spanish
5: Spanish
6: Portuguese
6: Portuguese
—
7: Chinese
Constant Access Level
A1-01
2
A1-01
2
A1-01
A1-01
0: Monitor Custom
0: Operation only
(monitors only)
1: User Selection Parameter
1: User Parameters *
2: QUICK-START (Q)
2: All parameters
3: BASIC (B)
4: ADVANCED (A)
* A2-01 through A2-32 Setting
User setting constant
A1-02
2
A1-02
2
A1-02
A1-02
0: V/f
0: V/f Control
1: V/f w/PG Control
1: V/f w/PG Control
2: Open Loop Vector
2: Open Loop Vector
3: Flux Loop Vector
3: Closed Loop Vector
─
5: Open Loop Vector for PM
─
6: Advanced Open Loop Vector
Control for PM
─
7: Closed Loop Vector Control
for PM
Initialize
A1-03
0
A1-03
0
A1-03
A1-03
0: No initialization
0: No initialization
1110: User Setting
1110: User initialize
2220: 2-wire sequence
2220: 2-wire sequence
3330: 3-wire sequence
3330: 3-wire sequence
─
5550: Reset OPE04
Enter Password
A1-04
0
A1-04
0000
―
Password 2
A1-05
0
A1-05
0000
―
User setting constant
A2-01 to
A2-32
─
A2-01 to
A2-32
―
If setting A1-01 to 1, refer to the manual and set parameters A2-01
to A2-32.