10 Appendix 2 Parameter Cross Reference
48
YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide
Digital Output Card
(DO-02, DO-08)
Channel 1 Output
Selection
F5-01
0*
F5-01
2*
*See the Comments column for H2-01 through H2-03.
Channel 2 Output
Selection
F5-02
1*
F5-02
4*
Output mode selection
F6-01
0
F5-09
0
F6-01
F5-09
0: Separate output for 8
channels
0: Separate output for 8
terminals
1: Binary Code Output
1: Binary Code Output
─
2: Output according to
F5-01 to 08
Pulse Monitor Card
Frequency Multiple
Selection
F7-01
1
H6-07
1440 Hz
F7-01
H6-07
0: 1F
Setting Range: 0 to 32000 Hz.
To have the pulse train output
and the output frequency be the
same, set H6-06 = 102 and
H6-07 = 0
1: 6F
2: 10F
3: 12F
4: 36F
SI-F/G
Communication
Option Operation
Selection
F8-01
1
─
─
A1000 does not support the SI-F/G Option Card.
SI-K2, SI-F/G
Communication Card
External fault input
level from Optical
option
F9-01
0
─
─
This parameter is not available in A1000, and therefore does not
need to be set.
External fault from
optical option
F9-02
0
F6-02
0
F9-03
F6-02
0: Always detected
0: Always detected
1: Detected during run
1: Detected during run
Action for external
fault from optical
option
F9-03
1
F6-03
1
F9-03
F6-03
0: Ramp to stop
0: Ramp to stop
1: Coast to stop
1: Coast to stop
2: Fast Stop
2: Fast Stop
3: Alarm Only
3: Alarm Only
Optical option trace
sampling time
F9-04
0
─
─
This parameter is not available in A1000, and therefore does not
need to be set.
Torque reference/
torque limit selection
from transmission
cards other than SI-K2
F9-05
1
F6-06
0
F9-05
F6-06
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Operation selection
when transmission
error detected for
transmission cards
other than SI-K2
F9-06
1
F6-01
1
F9-06
F6-01
0: Ramp to stop
0: Ramp to stop
1: Coast to stop
1: Coast to stop
2: Fast Stop
2: Fast Stop
3: Continue operation
3: Continue operation
Multi-Function Input
Multi-Function Digital
Input Terminal S1
Function Selection
─
─
H1-01*
40
Use this setting
H1-01 to H1-06
H1-01 to H1-08
0: 3-wire sequence
0: 3-wire sequence
1: LOCAL/REMOTE selection 1: LOCAL/REMOTE selection
2: Option/Drive selection
2: Run command source
b1-15
b1-16
3: Option card 3: Option card
3: Multi-Step Speed Reference
1
3: Multi-Step Speed Reference
1
4: Multi-Step Speed Reference
2
4: Multi-Step Speed Reference
2
Multi-Function Digital
Input Terminal S2
Function Selection
─
─
H1-02*
41
Use this setting
5: Multi-Step Speed Reference
3
5: Multi-Step Speed Reference
3
6: Jog freq ref selection
6: Jog freq ref selection
7: Accel/Decel Time Selection
1
7: Accel/decel time selection 1
8: Baseblock command (N.O.)
8: Baseblock command (N.O.)
9: Baseblock command (N.C.)
9: Baseblock command (N.C.)
A: Hold Accel/decel stop
A: Hold Accel/decel stop
B: Drive overheat alarm
B: Drive overheat alarm
Parameter Name
G5
A1000
Comments (Gray shading indicates default settings)
No.
Default
No.
Default
G5
A1000