195

Pr

ocessing

DXF

Files (Sof

tw

ar

e

Option)

Basic settings

The third soft-key row has various possibilities for settings:

Setting

Soft key

COLOR NORMAL/INVERTED: Switch the color
scheme

3-D MODE/2-D MODE: Toggle between
2-D and 3-D modes

Unit of measure MM/INCH: Enter the unit of
measurement of the DXF file. The TNC then outputs
the contour program in this unit of measurement.

Set the tolerance. The tolerance specifies how far apart
neighboring contour elements may be from each other.
You can use the tolerance to compensate for
inaccuracies that occurred when the drawing was
made. The default setting depends on the extent of
the entire DXF file.

Set resolution: The resolution specifies how many
decimal places the TNC should use when generating
the contour program. Default setting: 4 decimal
places (equivalent to 0.1 µm resolution)