57

1

.4 Stat

us Displa

ys

Tool measurement (TT tab)

Coordinate transformations (TRANS tab)

See “Coordinate Transformation Cycles” on page 438.

The TNC only displays the TT tab if the function is active
on your machine.

Soft key

Meaning

No direct
selection
possible

Number of the tool to be measured

Display whether the tool radius or the tool length
is being measured

MIN and MAX values of the individual cutting
edges and the result of measuring the rotating
tool (DYN = dynamic measurement)

Cutting edge number with the corresponding
measured value. If the measured value is
followed by an asterisk, the allowable tolerance in
the tool table was exceeded

Soft key

Meaning

Name of the active datum table

Active datum number (#), comment from the
active line of the active datum number (DOC) from
Cycle G53

Active datum shift (Cycle G54); The TNC displays
an active datum shift in up to 8 axes

Mirrored axes (Cycle G28)

Active basic rotation

Active rotation angle (Cycle G73)

Active scaling factor/factors (Cycles G72); The
TNC displays an active scaling factor in up to 6
axes

Scaling datum