beautypg.com

HEIDENHAIN iTNC 530 (340 49x-03) ISO programming User Manual

Page 10

background image

10

Functions included in 340 49x-01
new since the predecessor versions
340 422-xx and 340 423-xx

„

A new form-based operating mode, smarT.NC, has been
introduced. These cycles are described in a separate user’s
document. In connection with this the TNC operating panel was
enhanced. There are some new keys available for quicker navigation
within smarT.NC (see “Operating panel” on page 47).

„

The single-processor versions supports pointing devices (mice) via
the USB 2.0 interface.

„

New CENTERING cycle (see “CENTERING (Cycle 240)” on page 294)

„

New M function M150 for suppressing limit switch messages (see
“Suppress limit switch message: M150” on page 269)

„

M128 is now also permitted for mid-program startup (see “Mid-
program startup (block scan)” on page 568).

„

The number of available Q parameters was expanded to 2000 (see
“Programming: Q Parameters” on page 505).

„

The number of available label numbers was expanded to 1000. Now
label names can be assigned as well (see “Labeling Subprograms
and Program Section Repeats” on page 490).

„

In the Q parameter functions D9 to D12 you can now also assign
label names as jump targets (see “If-Then Decisions with
Q Parameters” on page 515)
.

„

The current time is also shown in the additional status display
window (see “General program information (PGM tab)” on page
54).

„

Several columns were added to the tool table (see “Tool table:
Standard tool data” on page 183).

„

The Test Run can now also be stopped and resumed within
machining cycles (see “Running a program test” on page 561).