11 Programming: Q Parameters

1

1

.1

0 Pr

eassigned Q

P

ar

amet

ers

Coolant on/off: Q111

Overlap factor: Q112

The overlap factor for pocket milling (MP7430) is assigned to Q112.

Unit of measurement for dimensions in the
program: Q113

The value of parameter Q113 specifies whether the highest-level NC
program (for nesting with %...) is programmed in millimeters or
inches.

Tool length: Q114

The current value for the tool length is assigned to Q114.

M Function

Parameter value

M08: Coolant ON

Q111 =1

M09: Coolant OFF

Q111 =0

Dimensions of the main program

Parameter value

Metric system (mm)

Q113 =0

Inch system (inches)

Q113 =1