Ii - 7 specifications for turning, Ii – 7 specifications for turning – HEIDENHAIN PT 880 User Manual
Page 141

POSITIP 880
141
II – 7 Specifications f
o
r T
u
rn
ing
II – 7 Specifications for Turning
POSITIP 880 Data
Axes
Up to 6 axes from A to Z, Z
0
, Z
S
Encoder inputs
6 x 11 µA
PP
, 1 V
PP
or EnDat (switchable); input frequency max. 100 kHz for
incremental or absolute HEIDENHAIN encoders
Signal period:
0.128 µm, 2 µm, 4 µm, 10 µm, 20 µm, 40 µm, 100 µm, 10 240 µm
Line count:
9 000/18 000/36 000
Subdivision factor
Max. 1 024-fold
Display step
Linear axes: 1 mm to 0.005 µm
Rotary axes: 1° to 0.0001° (00°00’01”)
Display
Color flat-panel display for position values, dialog and input display, graphic
functions, graphic positioning aid
Multi-lingual text
Status display:
Tool number
Diameter display Ø
Sum display
Functions
REF reference-mark evaluation for distance-coded or single reference marks
Distance-to-go mode, nominal position input (absolute or incremental)
Contour monitoring with magnify function
Scaling factor
HELP: On-screen operating instructions
INFO: Calculator, taper calculator, user and operating parameters
1 datum point, 99 tools
Freezing tool position for back-off
Oversize allowance
Programming
Up to 999 program blocks in each program; sub programming capability; teach-
in programming
Cycles:
Lines, arcs, chamfers, multipass turning, blend
Error Compensation
Linear and non-linear, up to 128 measuring points
Data interface
Serial:
RS-232-C/V.24 300 to 115 200 baud
For output of programs, measured values and parameters;
For input of programs and parameters
Parallel:
Centronics for output of measured values
Switching inputs/outputs
Upon request (via separate AMI input/output unit)