136

II Technical Information

II – 5 Measur

ed V

a

lue Output

Example 2: Rotary axis with degrees decimal display C =
+ 1260.0000°

1

Coordinate axis

2

Equal sign

3

+/– sign

4

4 to 8 places before the decimal point

5

Decimal point

6

0 to 4 places after the decimal point

7

Blank space

8

W for angle (in distance-to-go display: w)

9

Carriage return

10

Blank line (Line Feed)

Example 3: Rotary axis with degrees/minutes/seconds display
C = + 360° 23' 45'' '

1

Coordinate axis

2

Equal sign

3

+/– sign

4

3 to 8 places degrees

5

Colon

6

0 to 2 places minutes

7

Colon

8

0 to 2 places seconds

9

Blank space

10

W for angle (in distance-to-go display: w)

11

Carriage return

12

Blank line (Line Feed)

Data output using Edge Finder

In the next three examples, measured value output is started with a
switching signal from the edge finder. Printing capability can be
turned on or off in the Job Setup parameter Measured Value Output.
Information from here is transmitted from the selected axis.

C

=

+

1 2 6 0

.

0 0 0 0

W

1

2

3

4

5

6

7

8

9

10

C

=

+

3 6 0

:

2 3

:

4 5

W

1

2

3

4

5

6

7

8

9

10

11

12