Electrical requirements

Voltage

100 - 240 Vac

Power

35 VA max.

Frequency 50/60 Hz (+/- 3Hz)

Fuse 800 mA/250 Vac, 5 mm x 20 mm, Slo-Blo (line and neutral fused)

Environmental

Protection (EN 60529)

IP 40 back panel

IP 54 front panel

Operating temperature

0° to 45°C (32° to 113°F)

Storage temperature

-20° to 70°C (-22° to 158°F)

Mechanical weight

3.2 kg (7.2 lb.)

Wiring the power connector (See Fig. II.1)


Hot leads: L and N
Ground:

Minimum diameter of power connection cable: 0.75 mm

2

.

Protective earthing

Preventative maintenance

No special preventative maintenance is necessary. For cleaning, wipe
lightly with a dry lint-free cloth.

Fig. II.1

Wiring the power connector

Fig. II.2

The protective conductor terminal on the
rear panel.

It is necessary to connect the protective conductor
terminal on the rear panel to the star point of machine
ground. Minimum cross-section of the connecting wire:
6 mm

2