These tables describe all operating parameters which you must set for
the encoders and measured value display. Most entries can be found
in the operating instructions for your encoder.

Example settings for HEIDENHAIN linear encoders with 11-µA

PP

signals

Example settings for HEIDENHAIN linear encoders with 1-V

PP

signals

Encoder

Signal period

Reference marks

CT
MT xx01

2

Single

LS 303/303C
LS 603/603C

20

Single/
1000

LS 106/106C
LS 406/406C

20

Single/1000

LB 302/302C

40

Single/2000

LIM 501

10 240

Single

Encoder

Signal period

Reference marks

LIP 382

0.128

MT xx81
LIP 481A/481R

2

Single

LIP 481X

2

Single

LF 183/183C
LF 481/481C
LIF 181/181C
LIP 581/581C

4

Single/5000

LS 186/186C

20

Single/1000

LB 382/382C
LIDA 18x/18xC

40

Single/
2000

VM 182

4

LIDA 10x/10xC

100

Single/1000

LIM 581

10 240

Single