Ii - 5 measured value output, Examples of character output at the data interface, Ii – 5 measured value output – HEIDENHAIN PT 880 User Manual
Page 135
POSITIP 880
135
II – 5 Measur
ed V
a
lue Output
II – 5 Measured Value Output
Examples of character output at the data
interface
If you have a PC you can retrieve values from POSITIP 880. For
activation, see Measured Value Output under Job Setup. In all three
examples, measured value output is started with Ctrl B (sent over
serial interface) or a switching signal at the EXT input (within
optional Auxiliary Machine Interface). Ctrl B will transmit the currently
displayed values in either DRO 1 or DRO2, whichever is currently
visible.
Data output using external signals
Example 1: Linear axis with radius display X = + 41.29 mm
1
Coordinate axis
2
Equal sign
3
+/– sign
4
2 to 7 places before the decimal point
5
Decimal point
6
1 to 6 places after the decimal point
7
Unit: blank space for mm, “ for inches
8
Actual value display:
R
for radius, D for diameter
Distance-to-go display:
r
for radius, d for diameter
9
Carriage return
10
Blank line (Line Feed)
X
=
+
4 1
.
2 9
R
1
2
3
4
5
6
7
8
9
10