background image

47

SSP-3801

User Guide

9 Click the Board/FPGA tab to display the revision number for the board and the build

numbers for the field-programmable gate arrays (FPGA) on the SSP-3801 card.

Monitoring the Input Status

The Input Status page allows you to monitor the quality of video and audio input feeds for
the SSP-3801 card. The video and audio inputs are compared with a reference input to
ensure that they match. If they do not match, this may trigger alarms (see

Managing card

alarms

on page 49).

To monitor the Input Status:

1 Select Status Information > Input Status. The Input Status page opens.

Fig. 4-2: Input Status page

2 Click the Reference tab to display the status of the timing between the reference signal

and the SDI input signals.

3 Select the Video Inputs tab to display the status of the video input feeds, the Fill and

Key inputs, and if the overall timing alarms have been triggered.

4 Select the Embedded Audio tab to display the status of the embedded audio for the A,

B, and Fill inputs.

5 Select the AES Audio tab to display the type and status of the AES audio for channels 1

and 2.

Monitoring the Output Status

The Video Outputs tab displays the current video standard being output from the SSP-
3801 card. This video standard is defined in Card Configuration > Input/Output menu, in
the Video Standard field.

To monitor the Output Status:

1 Select Status Information > Output Status.

Fig. 4-3: Output Status page

2 The Video Output tab displays the current video output standard.