beautypg.com

Monitoring environmental policy – Grass Valley Network Attached Storage System Serial ATA Network User Guide v.1.0.06 User Manual

Page 85

background image

Chapter 7

System Administration

84

Digital News Production

Monitoring Environmental Policy

Use this window to configure temperature thresholds and to specify if a
shutdown should be initiated when the thresholds are breached. A threshold is
breached if the temperature goes above the hard or soft upper limit, or below
the hard or soft lower limit. Violating a threshold causes an event to be
generated, posted in the event log, an e-mail or a trap sent if SMTP and/or
SNMP services are active. Violating a hard threshold, if the Init Shutdown box
is checked, shuts down the appliance.

1. Change any threshold limit. Configure any of the temperature thresholds

listed below for the CPU or the system. The temperature values are in
Celsius, and must be positive numbers less than, or equal to, 78.

2. Specify if threshold violations should initiate a shutdown. A check in the box

for CPU or System directs DiMeda to shutdown when a temperature
threshold is violated.

3. Click

Save

to set new parameters and exit the window.

Field

Description

Lower Critical

The default value is 0 for the CPU and System. This value must be
less than the lower warning threshold.

Lower Warning

This value must be less than the upper warning threshold.

Upper Warning

This value must be lower than the upper critical threshold.

Upper Critical

The default value is 78 for CPU and 65 for the System.