beautypg.com

Refer to, To se – Grass Valley 8943RDA User Manual

Page 26

background image

26

8943RDA/-D/-DFR — Instruction Manual

Power Up

Refer to

Table 5

for a description of each front edge LED and how it oper-

ates. LEDs present on specific module are illustrated in the figures listed
below.

Note

Some LEDs, such as the FAULT LED, must report a collective state for all four
channels. This collective state is outlined in

Table 6 on page 27

.

8943RDA (

Figure 19 on page 42

)

8943RDA-D (

Figure 24 on page 52

)

8943RDA-DFR (

Figure 28 on page 61

)

Table 5. Front Edge LED Indicators

LED

Indication

Condition

STATUS LEDS

FAULT

(red)

Off

Collective module state of pass

On continuously

Collective state of internal fault

Flashing

Collective state of warning

COMM

(yellow)

Off

No activity on frame communication bus

Double flash

Location Command received by the module from a remote control system

Continuous short flash

Activity present on the frame communication bus

CONFIG

(yellow)

Off

No configuration change is in process, initialization complete

On

Module is initializing or changing operating modes

Double flash

In unison with COMM LED, Location Command received by the module from a remote
control system

PWR

(green)

Off

No power to module or module’s DC/DC converter failed

On continuously

Normal operation, module is powered

CH 1-4 PRESENT

(Green)

Off

No carrier

On Continuously

Energized signal present

CH 1-4 3G

(Blue)

Off

Signal present on CH 1-4 input is not detected as 3 Gb/s (carrier is way off frequency)

Flashing

Occurs when the mode is set to manual bypass

On Continuously

Signal present on CH 1-4 input is detected as 3 Gb/s

CH 1-4 HD

(Yellow)

Off

Signal present on CH 1-4 input is not detected as 1.485 Gb/s (carrier is way off fre-
quency)

Flashing

Occurs when the mode is set to manual bypass

On Continuously

Signal present on CH 1-4 input is detected as 1.485 Gb/s

CH 1-4 SD

(Yellow)

Off

Signal present on CH 1-4 input is not 1.485 (carrier is way off in frequency)

Flashing

Occurs when the mode is set to manual bypass

On Continuously

Signal present on CH 1-4 input is detected as 270 Mb/s

OPT MOD_1

(Yellow)

(8943RDA-DFR only)

Off

No SFP fiber optic submodule is installed or the SFP installed in the first SFP position
has a fault as noted on Status web page

On Continuously

A supported SFP submodule is installed in the top SFP position (see

Table 1 on page 14

)

for supported types)

Flashing

An unsupported SFP submodule is installed in the top SFP position

OPT MOD_2

(Yellow)

Off

Not used in this version

On

This manual is related to the following products: